Microbial growth analyzer Bioscreen C displays growth curves and microbiological calculations in MS Excel. Almost any strain can be used. 200 samples at time.

Microbiology Reader Bioscreen C

What is a Microbiology Reader Bioscreen C ?

Bioscreen C is an incubator and a culture growth monitoring device (OD reader) for 200 samples in one box.

Microbiological growth curves (turbidity versus time charts) and sophisticated microbiological calculations are generated directly to over 20 MS Excel sheets automatically.

click to open a larger picture of Microbiology Reader Bioscreen C

Microbiology Reader Bioscreen C

 

It is a well known principle that as microorganisms grow, they increase the turbidity of their growth medium. By measuring the turbidity of this medium over time, an optical density (OD) curve can be generated. The curve reflects the growth (increased concentration) if the organism of interest.

Bioscreen system provides a platform for these measurements to be made. The organism of interest and any growth medium may be selected. They are manually dispensed using a multichannel pipette into wells of a special microplate. 

Almost any experiment where the growth of bacteria, yeast, fungi, cell or phage are wanted to follow kinetically can be performed with Bioscreen C.

Bioscreen C Analyzer
The instrument includes an incubator to provide constant temperature and a linear shaker to assure good mixing. The instrument is equipped with a sensitive reader that measures turbidity, a technique more sensitive than a spectrophotometer. The reader is equipped with 8 filters to measure specific wavelengths. Two 100 well sterile honeycomb plates with covers are handled by the instrument at one time, making it possible to run 200 samples simultaneously. Turbidometric measurements are made kinetically during the course of the run. This information is processed to generate microbiological growth curves, plotting turbidity vs. time. Data is then exported to a PC (to MS Excel) for report generation.

Unique microbiological workstation for all needs
Bioscreen C is extremely versatile, it is a whole workstation with incubator, shaker, dispenser, turbidity reader all in one instrument. With Bioscreen C any micro-organism can be grown in any liquid growth medium and with any chemical by using user created test protocols. Additionally, the test length may vary from a single measurement to three months. Bioscreen makes it possible to complete as many tests in just a few weeks as would normally take a year using traditional microbiological techniques.

Honeycomb Microplate
This 10 by 10 well plate is designed to provide a uniform temperature across each of the 100 wells in the plate. A fitted plate lid with special characteristics eliminates troublesome condensation which can interfere with OD readings.

Turbidity and color reader
Bioscreen C measures culture turbidity, which indicates bacterial count better than the measurement of culture color. Turbidity is measured by a wide band filter which is rather insensitive to color change in the sample. For color measurement Bioscreen C has 7 other filters with special wavelengths.

Incubator and optional dispenser
A heating/cooling system provides a wide range of incubation temperatures (1.0-60.0 °C), and the temperature can be changed during the experiment. The special technology guarantees that there is no condensed liquid on the lower side of the multiwell plate cover. Bioscreen has an optional automated sterile dispensing feature. Sterilization of tips and tubing can be programmed for each step.
 

Bioscreen C uniqueness:
By special technique a condensation on plate cover is eliminated and a cover can kept on multiwell plates during whole run without loss in OD measurement quality.

 

Bioscreen C monitors turbidity (i.e. growth) of 200 samples kinetically, generates automatically microbiological growth curves (turbidity versus time graph) and performs microbiological calculations. All data is collected directly into MS Excel.

Bioscreen C is a useful automation tool to almost all of microbiology research labs and to many industrial/routine labs, too.

Bioscreen C makes it possible to complete as many tests in just a few weeks as would normally take a year by using traditional microbiological techniques.

• Excellent tool for microbiological research

• Open system for almost any broth culture of bacteria, fungi, yeast, cell or phage

• Whole workstation: incubator, shaker, dispenser and reader

 

 

Microbiology Reader Bioscreen C Technology Photos

(click thumbnail for larger view)
Microbiology Reader Bioscreen C. Microbiology Reader Bioscreen C. Microbiology Reader Bioscreen C. Inside look.   Bioscreen C runs 200 growth curve experiments at time - samples are in honeycomb format plates. Sample plates (2 pcs) and sample strips in incubator cassette.


Larger collection of Bioscreen C technology photos...

 

Bioscreen C Technical Specifications

Microplates: Thermo Labsystems Honeycomb 2

Incubating capacity: 2 plates/200 wells

Incubating temperature: 1-60 °C in 0.1 °C increments

Filters: 8 filters: from 405 to 600 nm and wide band

System recommendations: PC with MS Windows and MS Excel

 


There are available 3 software for a Bioscreen C:

  1. Included free software: EZExperiment
        http://www.bioscreen.fi/freesofware.html
     

  2. Commercially available software: Norden Lab Bioscreen C Edition
        http://www.bioscreen.fi/comsoftware.htm
     

  3. Commercially available software: Transgalactic Ltd Research Express
        http://www.transgalactic.com

 

A demo software Research Express for Bioscreen C
... can be downloaded on Download Page (select a first item "Software Research Express for microbiology reader Bioscreen C").

 

Computer Requirements of software Research Express

 

 

   Scientific Publications - Work Done by Microbiology Reader Bioscreen C

Agricultural Microbiology
Anaerobic Microbiology
Antimicrobial Susceptibility
Artificial Atmosphere
Bioassay of Antibiotics
Biofilm Microbiology
Bioreactor Technology
Biotechnology
Cell Biology
Clinical Microbiology
Environmental Microbiology
Experiments with Yeast
Fermentation
Food Microbiology
Functional Genomics
Gene Technology
Growth Media Development
Growth Rate and Lag Time
Industrial Microbiology
Medical/Pharmaceutical Field
Microbiological Assay
Microbiological Research
Microbiology of Cosmetics

go to a specific theme...

Military Microbiology
Molecular Microbiology
Mutagenicity and Genotoxicity
Oral Microbiology
Patents
Postantibiotic Studies
Soil Microbiology
Spore Microbiology
Veterinary Microbiology
Waste/Wastewater Treatment
Water Microbiology
Wine Microbiology

 


 

© 2005 Transgalactic Ltd (manufacturer of Bioscreen C software) | Privacy Statement | P.O. Box 1393, 00101 Helsinki, Finland, phone: +358 9 85172920, fax: +358 9 8749481, e-mail: microbiology@bionewsonline.com
 

 

 

Last modified: May 26, 2005